and Privacy Policy apply to you. Basic steel stud cutting tips and metal stud framing details. You can customize your base building package outlined above with doors, windows, insulation, skylights, siding and hundreds of other building options. A general description of lightweight steel framing products is presented along with a review of the advantages of this type of construction. At Bailey Metal Products Limited, we understand that every project is a chance to build on our reputation. Last chance to save up to 30% on these sizes. The metal roofing panels shown in this manual require a mini- mum slope of 2½” per foot to ensure proper drainage. A general description of lightweight steel framing products is presented along with a review of the advantages of this type of construction. Cut the metal studs and tracks. For over 60 years we have been recognized as the industry leader; offering building solutions to both commercial and residential structures. This guide has been prepared to assist practicing structural engineers and architects to design steel stud brick veneer systems for commercial and high rise residential buildings. Learn how to become one of our preferred "General" contractors or an independent dealer today. As Seen on TV! MBA Metal Framing > CAD Details > Structural Metal Studs and Track The MBA Metal Framing CAD Details below are complete drawings that can easily be downloaded, customized for your residential or commercial project, and included in your CAD library for future use.                     and Privacy Policy are applicable to you. Terms of Use Metal Stud Sizes. Photo 1: Cut the metal studs and tracks. .4.5 Wall Design R60 Joist Design R505 Rafter Design R804 Header Design Standard for Cold-Formed Steel Framing – Header Design R60 .6 Truss Design Standard for Cold-Formed Steel Framing – Truss Design Call 509-343-9019 for .dwg files. This area has the most up to date product literature, guide specifications, case studies, design and detail drawings, fire performance and acoustic rating information you will require. The most common shapes are diagrammed below, with dimensions. MBA Metal Framing > CAD Details > Structural Metal Studs and Track MBA Metal Framing Structural Metal Studs and Track CAD Details The MBA Metal Framing CAD Details below are complete drawings that can easily be downloaded, customized for your residential or commercial project, and included in your CAD library for future use. The most common size stud is a 3 5/8" wide stud. Framing members should be straight, true and of uniform dimension. NL2 Sill and Head Track Connection Detail NL3 Corner Framing Detail NL4 Slammer Stud Detail NL5 Window Opening Framing Detail NL6 Door Opening Framing Detail NL7 Non-Load Bearing Opening NL8 Non-Load Bearing Wall Parallel to Joist Roofs (Rafters/Joists): R1 … Refer to the rain- carrying table in this booklet for the maximum allowable panel length per slope that will provide adequate drainage. the steel stud knockouts, by using two layers of gypsum board, or by decreasing the stud spacing. 2. The following files contain generic details for Lightweight Steel Framing assemblies: We've always got something great going on. Selection of steel stud size is usually derived from limiting height tables,based on Bailey PLATINUM PLUS™ Steel Stud & Track for Drywall Framing, EASYCLIP™ S-SERIES™ AND E-SERIES SUPPORT CLIPS, Econo- Connector Surface Mount Brick Ties, Universal Bridging Clip (UBC 365, UBC 600, UBC800), Latest and greatest products and product innovations, Specials/Promotions specific to the Bailey Community, Download - Lightweight Steel Framing Architectural Design Guide, Download - Steel Stud Brick Veneer Design Guide, Bailey Lightweight Steel Brochure Wind Bearing, Bailey Lighweight Steel Brochure Axial Load Bearing, Bailey Lightweight Steel Framing Details - Brick Connectors, Bailey COMSLAB® Composite Floor System - Details, Criteria for the Design of Composite Slabs. Although each method has its plus points, metal stud framing has several aesthetic and functional advantages that make it a popular choice over wood stud. Combined with a layer of 5/8" gypsum wall board on both sides will give a 4 7/8" thick wall. Shaftwall / C-H Stud … 1. All Rights Reserved. They have height limits as shown in Table 1 and Table 2. 3. Our devotion to serving the Canadian market with innovation, quality and value has created a strong Bailey brand which construction markets rely on. Bottom Track Anchorage - Low Velocity Fastener, Bridging - Cold-rolled Channel with Angle Clip, Bridging - Double Flat Strap with Blocking, Bridging - Single Flat Strap with Blocking, Deflection Track Assembly - Double Deflection Track, Deflection Track Assembly - Single Track with Cold-rolled Channel, Door - Load Bearing, Back to Back Header, Back to Back Jamb, Door - Load Bearing, Back to Back Header, Boxed Jamb, Door - Load Bearing, Back to Back Header, Single Jamb, Door - Load Bearing, Boxed Header, Back to Back Jamb, Door - Load Bearing, Boxed Header, Boxed Jamb, Door - Load Bearing, Boxed Header, Single Jamb, Door - Load Bearing, Single Header with Strongback, Back to Back Jamb, Door - Load Bearing, Single Header with Strongback, Boxed Jamb, Door - Load Bearing, Single Header with Strongback, Single Jamb, Door - Non-Load Bearing, Single Track Header, Back to Back Jamb, Door - Non-Load Bearing, Single Track Header, Boxed Jamb, Door - Non-Load Bearing, Single Track Header, Single Jamb, Non-Load Bearing Interior Wall - Framed Above Ceiling with Diagonal Kicker, Non-Load Bearing Interior Wall - Framed to Ceiling with Diagonal Kicker, Spandrel Curtain Wall - Sticker with Vertical Drop and Diagonal Brace, Spandrel Framing at Pony Wall at Steel Post with Embed, Wall Framing at Corner - Track Lap Connection, Window - Load Bearing, Back to Back Header, Back to Back Jamb, Window - Load Bearing, Back to Back Header, Boxed Jamb, Window - Load Bearing, Back to Back Header, Single Jamb, Window - Load Bearing, Boxed Header, Back to Back Jamb, Window - Load Bearing, Boxed Header, Boxed Jamb, Window - Load Bearing, Boxed Header, Single Jamb, Window - Load Bearing, Single Header with Strongback, Back to Back Jamb, Window - Load Bearing, Single Header with Strongback, Boxed Jamb, Window - Load Bearing, Single Header with Strongback, Single Jamb, Window - Non-Load Bearing, Single Track Header, Back to Back Jamb, Window - Non-Load Bearing, Single Track Header, Boxed Jamb, Window - Non-Load Bearing, Single Track Header, Single Jamb. Studs and joists must be in true alignment; bridging, fire stops, soil pipes, etc., must not protrude beyond framing. Framing Standards. DESIGNED BY INTEGRA DESIGN STUDIO - POWERED BY PAVLIKS.COM. Founded in 1950 by Sam Bailey, Bailey Metal Products Ltd. is a family owned and operated Canadian company. © 2019 ARCAT, Inc.  All rights reserved. From our simple 3 step building quote to our growing library of project resources, General Steel is the company you've been looking for. For easier electrical and … Grow your business with General Steel! In the case of steel framing, the cross-sectional shape of the frame member, size and the thickness and grade of steel must be considered. Terms of Use Equally important are height of the wall, the frame spacing and the maximum span of the surfacing material. Framing Standards. .1.1(4), R 01. . This publication was written to assist practicing Architects with the selection, design and detailing of wall and floor systems incorporating lightweight steel framing (LSF) members for low rise commercial as well as medium and high rise residential applications. Low rise residential buildings are excluded because they generally have less exposure to environmental and structural loads. 2. SCAFCO Products CAD Details. Metal stud wall framing, also known as light-gauge steel framing, is an alternative to wood framing and has been standard in commercial construction in the US since the 1950s. Building science issues are discussed and the application of these principles is illustrated in a specific way for masonry veneer steel stud systems in low-rise commercial construction. Explore our kits page where you can filter by building type and learn how the base building package outlined above can be adapted for any intended use.  Back to back header reduces web-crippling reinforcement requirements. Cut both side flanges of a steel stud, using straight-cut aviation snips. It is the logical compliment to "Lightweight Steel Framing Design Manual" available from the CSSBI as a design guide for Structural Engineers. The Bailey Group of Companies is recognized as the industry leader, offering building solutions to both the commercial framing and drywall finishing residential markets. The standard features that make up your metal building system from General Steel are second to none when measured on the basis of material quality and ease of construction. © 2020 General Steel. 10639 W. Bradford Road Littleton, CO 80127. Use standard 25- and 20-gauge studs for interior partitions. SSMA Standard CAD Details After reviewing the framing and components that make up your building system, explore how these 5 primary areas of focus result in 5 advantages your project will benefit from.